Specifications include, but are not limited to: - Excavate soil and install footer.; - Install new brick veneered signs with pre-cast caps to measure 10’ wide by 4’ tall above grade; - Install sign panel with vinyl lettering.; Specifications: - Exact locations and orientation of each sign will be determined by an APSU representative and the contractor prior to excavation.; For each sign: - Dig footer at 24” wide and 12” deep.; - Footer to be poured with 4,000 psi concrete and reinforced to code.; - Install the core of the sign wall with CMU block. Wall should be vertically reinforced with rebar and empty cavities filled with concrete.; - Install brick veneer using Boral brick, Full Range Color, Wire Cut. Brick should be installed from below grade to the top on both sides of the CMU wall.; - Install a pre-cast concrete cap to match existing caps on campus. Example below.; - Provide and install 6’6” wide x 2”6’ tall, black, aluminum composite sign panel with metallic gold vinyl lettering; - Lettering should read: “JOE AND CATHI MAYNARD FAMILY ATHLETICS COMPLEX”; - Back fill with clean topsoil and re-seed with tall fescue.; - A proposed schedule of work must be discussed prior to beginning project.; - APSU Physical Plant Staff will work with successful contractor to coordinate exact dates and notify campus community of any sidewalk closures.