Specifications include, but are not limited to: The City of Bowling Green, Kentucky is soliciting bids for the full renovations of three sets of restrooms in the Sloan Convention Center located at 1021 Wilkinson Trace in Bowling Green, Kentucky. Bathrooms shall be renovated two at a time, while leaving four operational at all times. All work associated with this project is spelled out in plans and specifications below, but includes flooring, walls, tile work, electrical, plumbing, new fixtures, partitions, etc. Respondents shall add a $50,000 allowance to their bid price for contingency, only to be used upon approval by the City of Bowling Green.; PLUMBING FIXTURE INSTALLATION: A. Assemble plumbing fixtures and trim, fittings, faucets, and other components according to manufacturers' written instructions.; B. Install fixtures level and plumb according to manufacturers' written instructions, roughing-in drawings, and referenced standards.; C. Install floor-mounted, floor-outlet water closets with closet flanges and gasket seals.; D. Install toilet seats on water closets.; E. Install wall-hanging, back-outlet urinals with gasket seals.; F. Install flushometer valves for accessible water closets and urinals with handle mounted on wide side of compartment. Install other actuators in locations that are easy for handicapped people to reach.; G. Install tanks for accessible, tank-type water closets with lever handle mounted on wide side of compartment.; H. Fasten wall-hanging plumbing fixtures securely to supports attached to building substrate when supports are specified, and to building wall construction where no support is indicated.; I. Fasten floor-mounted fixtures to substrate. Fasten fixtures having holes for securing fixture to wall construction, to reinforcement built into walls.; J. Fasten recessed, wall-mounted fittings to reinforcement built into walls.; K. Fasten wall-mounted fittings to reinforcement built into walls.; L. Fasten counter-mounting plumbing fixtures to casework.; M. Secure supplies to supports or substrate within pipe space behind fixture.; N. Set shower receptors and mop basins in leveling bed of cement grout.; O. Install individual stop valve in each water supply to fixture. Use gate or globe valve where specific stop valve is not specified.; 1. Exception: Omit stop valves on supplies to emergency equipment, except when permitted by authorities having jurisdiction. When permitted, install valve chained and locked in OPEN position.