Specifications include, but are not limited to: complete paint removal, encapsulation, enclosure, and/or whole component removal of lead-based paint hazards as identified in the lead based-paint inspection report and other incidental work as may be necessary to satisfactorily complete the project as outlined or implied in the Design Specifications; 1 FCA-Unit Entry & Basement Doors- Replace with 90 Minute Fire Rated B1, B2, B3, C1, C2, D1 & D2 7 2 B-side Porch Floor- Replace Skirt Board with PT and Flooring with T&G fir flooring, (Solid Stain to Match, 2 coats) B Side 1 floor (4.5’x18‘) = 81 sq.ft. 18 lin. ft. / 81 sq. ft. 3 A-side Porch Floors- Replace Flooring with T&G fir flooring, (Solid Stain to Match, 2 coats) A Side 2 floors (6’x16’) = 192 sq.ft. 192 sq. ft. 4 Apt.5 Balcony Floor-Remove Rubber Membrane and flooring/ Install waterproofing membrane on roof & Add 2x PT sleepers with T&G fir flooring, (Solid Stain to Match, 2 coats) (6 sided floor w5.5‘ per side) < 79 sq. ft. < 11’ across points 5 A Porch Guardrails- Replace balustrades with Black Iron Rails A Side 1 floor (2 @ 4’ and 2 @ 2’) A Side 2 floor (2 @ 4’, 2 @ 2’ and 1 @ 9’) 33 lin. ft. (9) pieces 6 Apt.122-5 Balcony GuardrailsReplace with Black Iron Rails (3 @ 4’) OWNER TO SUPPLY RAILINGS BASED ON CONTRACTOR MEASUREMENTS 12 lin. ft. (3) pieces.