Specifications include, but are not limited to: 1. Tower Mapping – contractor shall complete a comprehensive tower mapping of tower steel structure itself, tower base/foundation, all guying anchor points, all guying hardware, all antennas, dishes, mounts, transmission lines, waveguides, cabling, cable management, hardware, tower lighting, grounding fixtures, tower climbing safety hardware and devices, and any other appurtenances attached to the tower structure. Deliverable will include drawings and a document listing all of the items specified above including manufacturer, part number, height above ground level, azimuth, and wind loading. Drawings will be provided in both paper, and electronic files including AutoCad dwg files. 2. Tower Structural analysis – contractor shall preform a structural analysis of the tower. The analysis must be performed by a certified Professional Engineer qualified to perform the structural analysis based on tower mapping data for the tower to determine the current capacity of the tower. Use ANSI/TIA 222-H standards for Communications Towers as the basis of the analysis. Deliverable will include structural analysis documents in writing for the tower detailing engineering data and documentation describing results of the towers structural analysis in the form of a written report to the IT Manager. 3. Additional Capacity Audit - contractor shall provide an analysis of the additional capacity of the tower that takes into consideration adding the equipment listed in Appendix B. 4. Preventative Maintenance List – contractor shall provide a list of preventative maintenance items such as inspections, tower leveling, etc., and include the schedule and duration for each task.