Specifications include, but are not limited to: Interior structural improvements for assembly occupancy: 1. Replace existing open-frame 2x4 studs @ 24” o.c. atop 56” high stone walls with new 4x4 posts @ 48” o.c. (26 posts @ approx. 6’-6” high) 2. Anchor stud wall to stone wall with ½” diameter X 5” embedded hilti hit HY 200 adhesive anchors at 48” o.c. along length of wall 3. Provide new ½” threaded rod X-bracing, 16’-0” wide in two locations; anchor with steel plates, clevises and turnbuckles 4. Provide new 2” average thickness concrete bonded topping slab throughout. 5. Selective demo of 4’-8” high stone wall (refer to plans) for new openings Shutter Detail: 1. 2x4 Pressure treated framing; mitered edges. 2. 5” barrel bolt, zinc plated. 3. 2 ½” Hinges, zinc plated. 4. 23/32” pressure treated pine plywood; stain or paint option 5. 3 ½” Latch post safety hasp, turn-lock, zinc plated. 6. Round pulls or handles