Specifications include, but are not limited to: 1.Elevator Testing and InspectionsThe Vendor shall perform all required State of New Hampshire inspections and safety tests,as determined by the State of New Hampshire, Department of Labor.2.Monthly InspectionsTwelve per year and/or each month. The Vendor must have at their disposal the properequipment to service the elevators including proprietary elevators listed in APPENDIX A.The Vendor will regularly and systemically examine the elevators, including oiling andcleaning machine, motor and controller, and other required items; cleaning of car tops andpits, hoist ways, door tracks, and other hoist way equipment; greasing or lubricating guiderails; minor adjustments and parts replacement disclosed as reasonably necessary at the time of regular examinations due to normal wear and tear to insure the safety and reliability of theelevators. All other work will be requested and authorized by the maintenance personnelrepresenting the utilizing agency.3.Fire Recall TestAs applicable: As part of the annual inspection, the Vendor shall coordinate with the StateAgency and the Fire Alarm Company for a fire recall test on the elevator.4.Hours of WorkStandard hours of work for this contract will be MON-FRI, 8AM – 5PM. Holidays areexcluded.