Specifications include, but are not limited to: Provide all labor, supervision, permits and materials to remove and replace 69 door slabs and hardware to match existing. Doors are fire rated. • Doors to be factory prepared and reinforced for all hardware installations. • Submittals required for each product indicated. Include construction details, material/hardware descriptions, core descriptions, hardware reinforcements, profiles, anchors, fire-resistance rating, and finishes. • Contractor to verify actual dimensions of each door and hardware arrangement to match with new. • NOTE: New door slabs are being installed into existing installed frames shim as necessary to comply with installation tolerances/clearances specified below. a. Jambs and Head: 1/8 inch plus or minus 1/16 inch. b. Between Bottom of Door and Top of Threshold: Maximum 3/8 inch. (if installed) c. Between Bottom of Door and Top of Finish Floor (No Threshold): Maximum ¾ inch. Fire-Rated Doors: Install doors with clearances according to NFPA 80. • Contractor to provide construction cores. Stanley BEST lock 7 pin cores