Specifications include, but are not limited to: BODY: The hopper shall have a minimum level capacity of Five (5) cubic yards. • The sides, ends and sills shall be unitized fully welded fabrication (side extensions not allowed) using minimum 10 gauge Stainless Steel (A certificate of compliance will be required from the successful vendor). • Bottoms of sills shall be formed outward to facilitate cleaning. • The front wall shall be sloped to eliminate bridging of material and the rear wall to be 90’ degree from the floor (not sloped). • Top of sides and ends shall be channel formed with welded mitered corners. • Each side shall be supported by at least four (4) ea. gussets formed from 7 gauge 304 stainless. Gussets to be stitch welded and staggered with a minimum of 4ʺ+/-1” overlapping beads on each side.