Specifications include, but are not limited to: 2.01 GENERAL REQUIREMENTS A. Potable Water Systems: Provide plumbing fittings and faucets that comply with NSF 61 and NSF 372 for maximum lead content; label pipe and fittings. B. Water Efficiency: EPA WaterSense label is required for all water closets, urinals, lavatory faucets, and showerheads. 2.02 FLUSH VALVE WATER CLOSETS (P-1) A. Water Closets: Vitreous china, ASME A112.19.2, floor mounted, siphon jet flush action, china bolt caps. 1. Bowl: ASME A112.19.2; 16.5 inches high with elongated rim. 2. Flush Valve: Exposed (top spud). 3. Flush Operation: Sensor operated. 4. Handle Height: 44 inches or less. 5. Supply Size: 1-1/2 inches. 6. Outlet Size: 2 inches. 7. Manufacturers: (SUGGESTIONS ARE LISTED BELOW. SUBMIT TO ENGINEER OF RECORD FOR APPROVAL)