Specifications include, but are not limited to: Cox Commercial Warm Air Furnace: SO 300K BTU Boyertown Furnace: Cabinet Height: 34 ¾ Cabinet Width: 89 Cabinet Depth: 31- 5/16 Warm Air Supply Width: 30 – 3/4 Warm Air Supply Depth: 27-5/16 Return Air Supply Width: 25 Return Air Supply Height: 25 Centerline Burner: 77 Centerline Flue: 38- 3/4 Centerline Flue to Side: 8-3/8 Center Burner to Side: 13-9/16 Output BTU/HR: 300.00 Input Oil G.P.H: 2.50 Nozzle Size: 2.00 70 B; Rework and install new supports for the installation of new furnace. Clean and vacuum existing ductwork before installation of new furnace. Hang and install new 300,000 BTU Boyertown oil furnace Rework existing supply and return ductwork and connect to new furnace Install new Beckett burner to furnace and rework and install oil lines from tank. Reinstall high voltage to new furnace and run new low voltage wiring to new thermostat Install new venting connections from furnace to chimney Install new spiral ductwork and material to provide heat to far side of garage Perform thorough start up and check out new system and provide combustion analysis