Specifications include, but are not limited to: The Contractor shall be responsible for all cutting and patching. The Contractor shall coordinate the work of the various trades involved. The General Contractor shall replace without expense to the Owner all glass broken during the construction of the project. If job conditions warrant, at completion of the job the General Contractor shall have all glass cleaned and polished. 18. The Construction Manager will supply a dumpster for the work, except as noted in the specific scopes of work. The contractor is responsible for placing debris in the dumpster. 19. Storage space will be limited. Materials and gang boxes cannot be in the way of other trades, traffic, fire lanes, access, etc. Review location and requirements with WT. Provide storage trailers or off site storage when necessary. 20. Furnish attic stock as required by the drawings, specifications, or the scope of work. 21. Jobsite security and security of materials, equipment, tools, etc. is the responsibility of each contractor. 22. Contractors are required to coordinate with other trades and with Whiting-Turner. 23. Contractors are required to comply with all safety regulations as required by OSHA, State of Delaware, Appoquinimink School District, Whiting-Turner, and as noted in the specifications. Provide all safety devices necessary for your work. 24. All change order pricing must be accompanied by a labor and material breakdown and with subcontractor & vendor quotes. 25. Care must be taken to not mark or damage finished surfaces. Contractors will be backcharged or will need to pay for repairs to the work of others. Protect the owner’s property. 26. Roof protection must be provided by any contractor working on top of the completed roof systems. Minimum protection required is 2” rigid insulation and ¾” plywood. 27. All safety, barricades, floor opening protection, etc., installed by this contractor or by others is the responsibility of this contractor if moved or damaged by this contractor. 28. Provide all testing, guarantees, warranties, as-built drawings, O&M manuals, commissioning tests, close-out documentation, and start-up services necessary to put all work into first class operating condition per the contract documents including any final cleanup required. 29. As-built drawings must be maintained on the job-site and updated on a daily basis for review by Whiting-Turner. At contract completion, contractor must submit as-built drawings and O&M Manuals as required by specifications. 30. Owner training required by specifications. Training must be videotaped.