Specifications include, but are not limited to: Walls - 8” Split-face block wall (contractor to provide sample colors to Township for review) reinforced with horizontal joint reinforcement. - Interior face to be primed with a masonry primer/sealer - 8” CMU foundation on 8” x 20” concrete foundation Floor - 4” Concrete floor with epoxy paint finish, slope to floor drain with 10 mil vapor barrier. Roof/Framing/Ceiling - Standing seam metal roof, match to pavilion for color/type (29 gauge painted steel, Grandrib 3+ profile by Fabral) - 2x6 wood roof and ceiling joists - 3” foil faced rigid foam insulation - ½” Moisture Resistant Drywall Ceiling, primed - Gable ends: ½” CDX plywood sheathing with vinyl siding, Use vinyl fascia boards, color to be determined by Township. - Provide white vinyl soffit (vented with ridge vent) - Gutter and downspout tied to existing roof leaders - 3 Solar Tubes Window/Door/Vent - 3’-0” hollow metal door with key code lock entry - 72” wide by 48” high roll-up metal shutter - 48” wide by 36” high vinyl slider window with steel security grill - PVC trim and brick molding. - 2- 8’x24” block vents