Specifications include, but are not limited to: Remove approximately 700sq. ft. of sidewalk and handicap ramp. Curbs to remain Reconstruction to existing sidewalk shall match the width of the existing sidewalk It is the vendor responsibility for all field measurements The sidewalk shall be composed of not less than four (4) inches of concrete using PennDOT Class A cement concrete, or High Early Strength Concrete of 4000 psi reinforced with wire A non-skid/broom finish shall be used The concrete sidewalk shall be placed on a 6” thoroughly compacted base of PennDOT No. 2A stone aggregate using wire mesh for reinforcement Rebar will be installed to the adjacent concrete sidewalk on either side of the block and curb to prevent shifting of concrete during expansion and contraction Expansion joints must be placed every 30 ft. Install 2’x 4’ Dimple Board at handicap apron Remove all debris from site Seal concrete after cured