Specifications include, but are not limited to: Perform inspection, lubricating, operating, servicing, adjusting, repairing and otherwise maintaining the structural and mechanical components of the Dam ; Complete monthly maintenance and inspect accessible portions of the intake structure and the stilling basin. Tighten any loose hardware found in the course of the inspection. Submit Inspection Report. Lubricate and operate all gates under head to 10% of their range (except middle and upper gates at PA 617, which are operated and maintained by Forest Park Water). ; Complete interior videotape inspection of intake structure, outlet conduit and stilling basin. Tighten any loose hardware found in the course of the inspection. Submit Inspection Report. ; Remove all debris from upper trash racks and screens.