1. Demolition and Removal ● Vendor shall remove and dispose of all existing interior doors, hardware, and frames included in this project scope. ● All demolition activities must be conducted in a manner that minimizes disruption to building occupants and preserves adjacent finishes and structures. ● Work areas shall be cleaned and cleared of all debris at the end of each workday. 2. New Door and Frame Installation ● For Classroom Doors: VT Industries FD-5 3’-0” x 7’-0” 45 Minute Positive Pressure Architectural Wood Doors x FNV Lite Cutout x G2A Cylindrical Leverset Preparation x Door Closer and Lock Blocking Finish: Standard Manufacturer Finish (To Be Determined) ● For Classroom Doors: Curries M16 3’-0” x 7’-0” 16 Gauge WHI-C Masonry Frame x HGCR Continuous Hinge Reinforcement x E11 Door Closer Reinforcement x E1 ASA Strike Preparation Finish: Factory Paint Per District Sample ● For Gymnasium Doors: VT Industries FD-5 Pair 2’-6” x 7’-0” 45 Minute Positive Pressure Architectural Wood Doors x FNV Lite Cutouts Door Closer and Exit Device Blocking Active Door Leaf: G12 Mortise Exit Device Preparation Inactive Door Leaf: G11a Surface Vertical Rod Exit Preparation (LBR) x Open Back Door Strike Finish: Standard Manufacturer Finish (To Be Determined) ● For Gymnasium Doors: Curries G16 5’-0” x 7’-0” 16 Gauge WHI-C Masonry Frame x HGCR Continuous Hinge Reinforcements x E11 Door Closer Reinforcements x E5 Surface Vertical Rod Strike Reinforcement Finish: Factory Paint Per District Sample ● All doors and frames must meet local, state, and federal building codes, including ADA and NFPA compliance. 3. Door Hardware Installation ● For Classroom Doors: Provide and install all required commercial-grade hardware, as follows: ○ ABH A1110HDC Continuous Hinge x 83” x Clear Aluminum Finish ○ Best 9K37-AB-14-K-S3 Classroom Function Cylindrical Leverset x Less Core x US26D Finish ○ Dorma 8916 Door Closer x DS x FC x SNTPK x 689 Finish ○ Hager 190S 8” x 34” Stainless Steel Kick Plate x US32D Finish ○ NGP L-FRA100 8” x 36” Lite Kit x Standard Manufacturer Finish (To Be Determined) ○ Firelite NT90 3/16” x 7” X 35” Fire Rated Glass ● For Gymnasium Doors: Provide and install all required commercial-grade hardware, as follows: ○ ABH A1110HDC Continuous Hinge x 83” x Clear Aluminum Finish ○ Precision FL2310VI Mortise Exit Device x 4908A x Intruder Function x Visual Indicator x 2’-6” x US32D Finish ○ Precision FL2201LBR Surface Vertical Rod Exit Device x Exit Only x 2’-6” x US32D Finish ○ Precision S984 Open Back Strike x US32D Finish ○ Best 12E-72 Rim Cylinder Housing x Less Core x US26D Finish ○ Best 1EA6A4 Mortise Thumb turn Cylinder x US26D Finish