Specifications include, but are not limited to: - Access Control Boards – (Quantity 10); Must be Mercury-compatible; Must be compatible with Genetec Security Center; 2 boards to replace current boards that support 1 door each; 2 boards to replace current boards that support 2 doors each; 2 boards to replace current boards that support 3 doors each; 1 board to replace current board that supports 4 doors; 1 board to replace current board that supports 7 doors; 1 board to replace current board that supports 9 doors; 1 board to replace current board that supports 11 doors - Card Readers - (Quantity 6); Must be compatible with Genetec Security Center; Power: DC 12V; Functions: Access control terminal; Interfaces: Relay output, Wiegand; Environment: Indoor/Outdoor; Features: 125 kHz, 13.56 MHz & 2.4 GHz card technology; Card Technology: AWID Proximity, Contactless e-Purse Application Specification (CEPAS), EM4102 Prox, FeliCa, HID iCLASS SE, HID iCLASS Seos, HID iCLASS SR, HID MIFARE Classic, HID MIFARE DESFire EV1, HID MIFARE DESFire EV2, HID Prox, Indala Prox