1) 50 each $________________ Unit Price $_______________Total Price SENSUS iPerl 3/4 X 3/4 inch short TR/PL meter with 6 feet of wire. 7.5” lay length. Solid state, battery operated electromagnetic flow measurement system with a hermetically sealed, glass covered, electronic register with a programmable 9-digit display. Meter to read in 100 cubic feet. Register to face inlet. Certified test report to be attached. Meter shall have dry register, no oil filled registers. The measuring element shall be made of a noncorrosive, lead-free glass fiber reinforced, composite alloy material. A battery powered magnetic flow sensor utilizing Farday’s law. System shall operate up to a working pressure of 200 pounds per square inch (psi), without leakage or damage to any parts. The accuracy shall not be affected by variation of pressure up to 200 psi. Data logger in register. Optional UL approval. 2) 50 each $________________ Unit Price $_______________Total Price SENSUS iPerl 1 inch TR/PL meter with 6 feet of wire. Solid state, battery operated electromagnetic flow measurement system with a hermetically sealed, glass covered, electronic register with a programmable 9-digit display. Meter to read in 100 cubic feet. Register to face inlet. Certified test report to be attached. Meter shall have dry register, no oil filled registers. The measuring element shall be made of a noncorrosive, leadfree glass fiber reinforced, composite alloy material. A battery powered magnetic flow sensor utilizing Farday’s law. System shall operate up to a working pressure of 200 pounds per square inch (psi), without leakage or damage to any parts. The accuracy shall not be affected by variation of pressure up to 200 psi. Data logger in register. Optional UL approval. 3) 800 each $________________ Unit Price $_______________Total Price Sensus SRII 3/4x3/4 inch short TR/PL meter with 6 feet of wire. 7.5” lay length. Meter shall have dry register, no oil filled registers. The register output data format shall be 7-bit ASCII (American Standard Code for Information Interchange) digital, plus an even parity bit. Upon interrogation with a Touchpad or AMR/AMI product, the register will transmit an odometer reading containing from 4 to 8 digits (field programmable) and a user defined alphanumeric identification of up to 12 characters (field programmable). Data logger in register for a minimum of 120 days. Register must be able to detect and alarm on register removal from the main body or any outside magnetic tamper. Encoders with a mechanical brush contact or “optical-sensing” technology with the odometer wheel will not be acceptable. The register can also be programmed to output a factory set, nonprogrammable identification number, Customer Text of up to 20 alphanumeric characters (field programmable), a reading multiplier ranging from 10-99 to 1099 (field programmable), and/or a reading measurement unit indicator (for example, US Gallons – field programmable). Data is to be positive true. The register’s ASCII digital output is to be capable of interfacing directly to an AMR/AMI transponder to transmit data via radio signal to an AMR/AMI system. 4) 100 each $________________ Unit Price $_______________Total Price Sensus SRII 1 inch TR/PL meter with 6 feet of wire. 7.5” lay length. Meter shall have dry register, no oil filled registers. The register output data format shall be 7-bit ASCII (American Standard Code for Information Interchange) digital, plus an even parity bit. Upon interrogation with a Touchpad or AMR/AMI product, the register will transmit an odometer reading containing from 4 to 8 digits (field programmable) and a user defined alphanumeric identification of up to 12 characters (field programmable). Data logger in register for a minimum of 120 days. Register must be able to detect and alarm on register removal from the main body or any outside magnetic tamper. Encoders with a mechanical brush contact or “optical-sensing” technology with the odometer wheel will not be acceptable. The register can also be programmed to output a factory set, nonprogrammable identification number, Customer Text of up to 20 alphanumeric characters (field programmable), a reading multiplier ranging from 10-99 to 1099 (field programmable), and/or a reading measurement unit indicator (for example, US Gallons – field programmable). Data is to be positive true. The register’s ASCII digital output is to be capable of interfacing directly to an AMR/AMI transponder to transmit data via radio signal to an AMR/AMI system.