The TF33 Engine Trailer Mount Set is a manufactured mounting bracket used to assist in transport of the TF33 engine during Programmed Depot Maintenance inside and outside of controlled aircraft hanger areas. The engine trailer mounts must be fabricated IAW with attached drawings. The drawing package is available & included as part of this market research.
Forward TF33 Engine TrailerMount Adapter – Engineering Drawing 200640504
Static / Dynamic Load Minimums: 4,500 pounds / 6,750 pounds
Coating Requirement: Powder-coated Safety Yellow –MIL-PRF-24712B Type III
Labeling Requirement:
- 1” tall black stencil with following messages included on trailer mount in accordance with (IAW) drawing
- “NOT FOR SHIPPING”
- “200640504”
Environmental Requirements:
- Able to withstand 10-110 degrees Fahrenheit
- Able to withstand up to 30 knot winds
- Weatherproof to withstand rain, snow, sleet, direct sunlight
Storage Requirements:
- Able to withstand outside storage / transportation per Environmental Requirements
- Coating & Material able to withstand UV Light while stored outside unprotected
Manufacturing Requirements:
- Able to withstand vibrations from tow/transport
- Rust-free, crack-free, and defect-free
- Meets all applicable AF1, AFOSH, and OSHA standards per Engineering Drawing
Aft/Rear TF33 Engine Trailer Mount Adapter – Engineering Drawing 200640505
Static / Dynamic Load Minimums: 1,200 pounds / 1,800 pounds
Coating Requirement: Powder-coated Safety Yellow –MIL-PRF-24712B Type III
Labeling Requirement:
- 1” tall black stencil with following messages included on trailer mount IAW drawing
- “NOT FOR SHIPPING”
- “200640505”
- “ENSURE NUT IS INSTALLED” “ENSURE PIN IS INSTALLED”
Environmental Requirements:
- Able to withstand 10-110 degrees Fahrenheit
- Able to withstand up to 30 knot winds
- Weatherproof to withstand rain, snow, sleet, direct sunlight
Storage Requirements:
- Able to withstand outside storage / transportation per Environmental Requirements
- Coating & Material able to withstand UV Light while stored outside unprotected
Manufacturing Requirements:
- Able to withstand vibrations from tow/transport
- Rust-free, crack-free, and defect-free
- Meets all applicable AF1, AFOSH, and OSHA standards per Engineering Drawing
This is a build to print acquisition. The Government anticipates utilizing a one-time contract. The projected quantities will not exceed 16 sets (16 total per part number) at this time.