Specifications include, but are not limited to: Acceptable Manufacturers: Hobart, Meiko, and Champion. Connected Load and Energy Consumption Machine electrical load requirements to include all electrical energy draw components including blower dryer, motors, and controls, collectively on (1) electrical connection, rated at 18.5 amps, requiring a minimum supply circuit and maximum protective device of 30 total amps. The tank heater and steam booster heater are to operate on 20# steam with a maximum consumption rate not greater than 280 lb/hr. Blower Dryer Heated blower dryer to include (1) 2 HP blower motor and side air diverter for consistent air flow. Blower motors to include sealed ball bearings and overload protection. Automatic Soil Removal Machine is to be equipped with an automatic soil removal system. This system will prevent soil buildup in prewash/wash tanks by actively pumping and automatically removing the food soil from the soil removal tank into an external basket that is isolated from all wash zones. Auto Delime Machine to be furnished with an automatic delime system. The machine will notify the operator when a delime cycle is required, based on the location’s specific water conditions. The process simplifies operator involvement by automatically distributing delime chemical throughout the machine after operator adds chemical to one tank. System automatically pumps chemical into rinse system to delime booster, energy recovery, and final rinse arms. Once the cycle is initiated, the machine will run for the necessary length of time, drain, refill, flush the interior, and drain automatically, with no further action required by the operator.