Specifications include, but are not limited to: To replace an access control system. replace the access on 102 doors or readers. Must provide a Virtual LenelS2 Net controller with 128 portal licenses. The LenelS2 Netbox system will work with the customers’ existing HID Corporate 1000 cards. Must install all horizontal wiring exposed above the drop ceilings and will conceal vertical wiring where possible, surface mounted wire mold or conduit may be needed. 1 S2-EX100-128 Required Item Includes 128 portal license in 1U rack mount server. 1 Each; 2 S2-NN-E2R-WM Required Item Wall mount enclosure with (1) S2 ACM blade and 6 available expansion slots. 11 Each; 3 S2-ACM-25; Required Item; 25 COUNT Access control application extension blade with support for 2 OSDP or 2 Wiegand readers, 4 inputs and 4 outputs (each blade). Can be used with S2-NN-E-WM/RM empty node enclosure. Th 1 Each; 4 S2-ACM; Required Item; Access control application extension blade with support for 2 OSDP or 2 Wiegand readers, 4 inputs and 4 outputs. 20 Each; 5 12V8AH; Required Item; BATTERY - 12V 8AH 11 Each; 6 5566030; Required Item; Cat 6 Pl 1000 Yellow 1 Each; 7 IC1078F6WH; Required Item; ICC Modular Connector, CAT 6, White 22 Each; 8 IC107SB1WH; Required Item; ICC Single Port Surface Mount Box 11 Each; 9 IC107BP241; Required Item; 24 Port Modular Patch Panel 4 Each; 10 ICPCSK01YL; Required Item; ICC Cat 6 1' Patch Cord, YELLOW 11 Each