Specifications include, but are not limited to: ROADWAY 1 202 Pavement Removed, Asphalt 48 S.Y. 2 202 Curb Removed 272 Foot 3 202 Walk Removed 2274 S.F. 4 202 Pullbox Adjusted to Grade 3 Each 5 202 Light Pole, Removed 1 Each 6 202 Catch Basin Removed 1 Each 7 209 Linear Grading, As Per Plan 0.1 Mile 8 611 Subgrade Compaction (As Per 611.06 & Supp. Spec. 1015) 345 SY 9 638 Valve Box Adjusted to Grade 4 Each PAVEMENT 10 304 Aggregate Base (4" Thick) 54 C.Y. 11 Spec 2.25" Landscaping Brick (including Leveling Sand) 160 S.F. 12 608 Curb Ramp, As Per Canton Std. Dwg. 33, (Cast Iron Domes) 293 S.F. 13 608 ADA Ramp Installation 6 Each 14 608 3" Concrete Walk 160 S.F. 15 608 5" Concrete Walk 3376 S.F. 16 609 Concrete Curb, As Per Plan 272 Foot 17 625 Pull Box, Misc: Lighting, 725.06, 17" x 30" 3 Each 18 625 2" Conduit, As Per Plan 224 Foot 19 625 3" Conduit, As Per Plan 224 Foot 20 625 4" Conduit, As Per Plan 14 Foot 21 625 Light Pole Foundation 2 Each 22 625 500' Spool 6AWG Copper Stranded, THHN (City to Install) 2 Each 23 SPCL Tree Grate Frame, As Per Plan 2 Each 24 661 Deciduous Tree, 1" Caliper, As Per Plan 2 Each STORM SEWER 25 611 Manhole Adjusted to Grade 3 Each 26 611 Curb Inlet Catch Basin, As Per Canton Std. Dwg. 1 1 Each 27 611 Catch Basin, Adjusted to Grade 1 Each TRAFFIC 28 642 Crosswalk Line, 12", Type 1 90 Foot INCIDENTALS 29 614 Maintaining Traffic, Complete 1 Lump 30 623 Construction Layout Stakes 1 Lump 31 624 Mobilization 1 Lump