ALVEY KS-88 INDUSTRIAL CART WASHER Brand name or Equal Scope of Work The contractor shall deliver the unit to the location stated below. Louis A. Johnson VAMC is drawing up a contract for renovation and the facility is seeking new equipment. Specifications Salient Characteristics: Features Include: Wash Chamber section Wash chamber 102 long, 36 wide, and 80 height Constructed of type 304 stainless steel with polished finish Panel-Z type interlocking double flange type seal Two counter-rotating stainless steel spinning arm assemblies Stainless steel wash nozzles Stationary fresh water rinse on top and sides with brass nozzles 23.5 gallons of fresh rinse water to replenish wash tank each cycle Wash Pump 15 HP TEFC (totally enclosed fan cooled) motor, vertically mounted pump delivering 400 GPM at 35 PSI Stainless steel wash and rinse pipes Pump protection screen Tank and Housing Tank constructed of 12 gauge type 304 stainless steel Housing constructed of 16 gauge type 304 stainless steel Removable stainless steel filter screens 225 gallon tank capacity (290 if gas heat) Door(s) Pass-Thru front and rear entry walk-through design 38 wide x 83 high opening Interior safety release latch Triple hung (3 hinges) for added durability Control Panel UL listed NEMA 4X stainless steel panel Three pre-set cycle times Automatic water fill Electronic temperature control Digital wash and rinse temperature indicators Wash and rinse pressure gauges Additional Features NSF certified Pit mounted design Safety guard rail Anti-slip floor Washer shipped knocked down for field assembly High capacity exhaust fan Wash down hose and nozzle Heating Stainless steel steam heated coils Warm rinse steam heat booster NOTE: Insulation (piping or otherwise) is not included and is to be provided and applied by customer. Pressure regulation of the gas, steam, and / or water utilities is required for proper operation of this equipment. Gas regulators and pressure reducing valves are not included and are the customer s responsibility to provide to ensure the specified operating pressures & ranges are maintained. Voltage 220/240V/3PH/60HZ Delivery Location Attn: (Beth Bova) BOVA Corporation 111 McFann Rd Valencia, PA 16059 Email: beth@bovacorp.com Prior to delivery, Contracting Officer Representative and/or Service Line Representative shall receive shipping information from Contractor and forward to Beth Bova and Logistics using the email(s) listed above. The Contractor must comply and provide all necessary information to VA Clarksburg. Otherwise, the delivery may be refused and require redelivery at no additional cost to the government. Requested Delivery Date Delivery of equipment is requested to occur with 60-days after receipt of order. While installation is not required, once our service installs the equipment, training will be required once it is scheduled by the service.