Infrared detectors only – no dual detector instruments INTOXILYZER ® 9000 • ANALYTICAL PRINCIPLE: Infrared Absorption • MULTIPLE WAVELENGTH: Analyzes samples using multiple IR wavelengths • RANGE: 0.000 to 0.650 gram/210 liters to 0.650 gram/210 liters • ACCURACY: ±3% or ± .003 grams/210 liters (whichever is greater) • PRECISION: Standard deviation of .003 or better • OPERATING SYSTEM: Microsoft Windows CE 6.0 • APPROXIMATE DIMENSIONS: w/Gas w/o Gas Length 19″ 14 ½” Width 14″ 14″ Height (lowered) 6 ¾” 6 ¾” • WEIGHT: w/Gas 12 lbs. w/o Gas 10 lbs. • EXTERNAL PRINTER: USB compatible PCL LaserJet • MEMORY: 128 MB RAM, 512 MB Nand Flash, Optional Internal SD Card slot for memory expansion up to 32 GB • REAL-TIME CLOCK: accurate to ±10 minutes per year • WARM-UP TIME: less than 20 minutes at 20°C • TEST TIME: less than 1 minute, excluding data entry • VIBRATION AND SHOCK: to IEC 68-1/2 • CASE CONSTRUCTION: impact resistant; must be able to withstand being dropped, thrown in the trunk of a patrol car, etc. • DISPOSABLE MOUTHPIECES: spit-trap individually wrapped • WARRANTY: Instrument has a standard one (1) year warranty.