Pathways in a lay-in ceiling environment can consist of J-hooks, caddy straps, conduit and/or open bottom cable trays. Pathways in an open ceiling environment can consist of conduit, raceway and/or closed bottom cable trays. Pathways existing or new, must maintain a 40% or less fill. All data cabling that leaves the building and is incased in any type of conduit or hung on J-Hooks under deck structures will have to be Outdoor Direct Burial type cable. 6. If conduit or sleeves are needed for this job, it will be the responsibility of the contractor to have it installed unless otherwise stated in the SOW. 7. All penetrations will require bushings and fire stop in accordance with Guilford County and applicable city fire codes. 8. All cabling, patch panels, racks, etc. shall be labeled according to GCS Cabling Specifications. 9. All cabling will be tested to meet or exceed GCS Cabling Specifications...