1.0 General Requirements LS 1 3.1 Floor Repair - Partial Depth SF 180 5.1A Superficial Beam Repair - Partial Depth SF 5 6.1 Column Repair - Partial Depth SF 5 7.1 Wall Repair - Partial Depth/Shallow SF 11 7.5a Spandrel Panel Connection Repair LS 1 7.5b Panel Connection Repair LS 1 7.6 Tee Stem Corbel Repair At Wall EA 3 8.1A Tee Stem Repair - Partial Depth SF 1 8.4 Tee Flange Repair - Partial Depth SF 100 10.3 Expansion Joint - Elastomeric Concrete Edged LF 300 10.5H Expansion Joint - Precompressed (Horizontal) LF Incidental to 44.1 N/A N/A 11.1 Rout & Seal Random Cracks LF 65 11.1A Rout & Seal Perimeter of Stair Opening LF 195 11.2 Repair Joint Sealant LF 9,040 11.3 Vertical/Horizontal Joint Sealant LF 85 11.5 Crack Repair - Epoxy Injection LF 10 11.7 Cove Sealant LF 5,615 15.1 Concrete Sealer - Floors SF 70,020 16.5 Traffic Topping - Recoat (Complete System) SF 10,265 16.9 Elastomeric Coating SF 230 35.1 Tuckpointing LF 60