3. Remove all existing shingles and felt down to the decking. 4. Install new felt paper (30#). 5. Install new StormGuard waterproof underlayment, or approved equal, per manufacturer’s installation instructions and guides. Use underlayment on the bottom course and in the roof valleys, in place of standard felt. 6. Install new 30-year asphalt architectural brown shingles and nails (limited lifetime warranty, wind rated, and fungal/algae-resistant). a. Shingles to be made by Certainteed, GAF, Owens Corning, or an approved equivalent. b. Provide manufacturer’s warranty. c. Final shingle color to be approved by City. 7. Replace all facias (2x6) with ground-contact pressure-treated lumber (non-painted). a. All facias must be screwed in, not nailed. b. Isabella Cannon #32 is excluded from facia scope since facias were recently replaced.