Replace fencing Around pump station site as needed with 6 'galvanized 9 gauge chain link with 3 strand barb wire around top. Install 4’ walk in gate on west side by parking area inward opening 180 degrees . Install “Stymielock”( 1.888.278.9643 Stymielock PO Box 1228 Pineville, NC 28134 ) on the gate with places for 2 locks. Fence Specifications ● 6’ overall fabric height.Plus 1' barbed wire overhang. ● Chainlink,2” mesh x 9 gauge to desired height. Manufactured from the highest quality galvanized wire,or vinyl coated. InaccordancewithASTM-A392-81-Class1. ● 17/8” O.D. galvanized pipe complete with post tops without barbed wire overhang arms. ● 13/8” O.D. galvanized pipe coupled with slip on rail sleeves for every standard length generally 21’ in length. ● End, corner and gate posts:27/8” O.D. galvanized pipe, furnished complete with all necessary bracing, fittings, etc. Gate posts for single gate panels over 8’ wide and double panels over 16’ )wide use 3 ½” O.D. pipe. Gate posts for single gate panels over 12’ )wide and double panels over 24’ wide use 4½” O.D. pipe. Gate posts for single gate panels over16’ wide and double panels over 32’ wide use 6 5/8” O.D. pipe. Note:All single gate panels over 10’ wide and double panels over 20’ wide require ASTMA-120 schedule 40 pipe ● Gate frames 1 5/8”O.D. galvanized pipe, welded construction to match fence. Complete with industrial steel hinges ,drop pin latch and one foot bolt on double panels. Hinges to permit opening 180 degrees one way.