Storefront Detail • The Contractor shall remove the existing double doors and framing and install an ADA compliant counter integrated with a new storefront system. All sheetrock work, framing, painting, trim, and necessary modifications shall be included. • The storefront system shall include two service areas, each featuring pass-through windows with aluminum, non-ballistic speak-throughs. All glass shall be 1/4” tempered storefront glass. Framing shall be aluminum storefront material. Countertop Detail • The countertop dimensions and materials are shown below. The top of the countertop shall be approximately thirty-five-inches (35”) from the finished floor. • It shall extend two-feet (2’) into the hallway area and one-foot (1’) into the office area. • All countertop edges shall be bullnosed, except the end that will tie into the wall. • Wooden countertop brackets shall be securely fastened into the countertop and wall to support the countertop. Door Detail • Remove the existing right-side window and install a thirty-six-inch by eighty-two-inch (36”x82”) flat faced metal exit only door and frame equipped with a crash bar, located inside the office. • The new door and frame shall be painted to match existing beige color. Office Area General Detail • New 8-inch (8”) black vinyl cove base shall be added where missing following the storefront installation. • The motion sensor located above the existing double doors shall be removed and given to the County POC. • The existing emergency exit sign with integrated emergency lights shall be removed and disposed. • Relocate the existing emergency exit wiring above the new door to install a new emergency exit sign with lights. Hallway Area General Detail • New one-inch by 8-inch (1”x8”) wooden trim with shoe molding shall be added where missing after the storefront installation. All new trim shall be painted to match the existing beige color.