Summary of Specifications:
CHEMICAL STORAGE LOCKER: COMPLY YES/NO Prefabricated Hazardous Material Storage Locker, 33 Drums/172 SqFt./644.8 Gal. Sump Capacity, Nominal Dimensions: 24’ x 8’x8’4”, snow Load: 40PSF, Floor Load: 500 PSF, Wind Load 130 MPH EXP. C
LOCKER CONSTRUCTION: Non-Combustible weatherproof construction
with welded exterior 12-gauge steel panels and 10-gauqe sump for maximum durability and strength. Wall studs are 3 ½” by 2” for superior strength, manufactured from 12 gauge steel and producing a 3 ½” wall cavity ready to accept standard insulation. Continuously welded roof and sump sections. __________
Roof/Ceiling: Non-combustible weatherproof construction same as building walls. Continuously welded 12 gauge steel roof permanently attached to building. Equipped with rain over door.
Spill Containment Sump Construction: Built in 7” deep leak tight secondary containment sump surpasses FM spill containment requirements. Heavy-duty construction utilizes 10 gauge steel structural support. Removable galvanized steel floor grating rated 500 psf for heavy drum/pallet loads. Structural steel floor supports are easily removed for cleanup of spills within the sump __________ Building Base: Open channel construction for under-sump inspection. Steel C channels and hold down brackets provided for ease of offloading and securing to site. Attains seismic and wind loading anchoring __________
Static Grounding Systems: Three (3) Interior grounding lugs, one (1) exterior static grounding connection and one (1)
galvanized steel grounding rod for prevention of explosive sparking hazards. __________
Ventilation: Gravity Air Flow Vents, in high low positions, with Weatherproof galvanized steel frame and louvers to provide adequate sir flow and natural draft, Interior screen openings to prevent past entry. __________
Building Finish: Interior and exterior surfaces protected with a (minimum) high performance 2 part epoxy base coat(primer) and a high finish modified urethane top coat , chemical, abrasion, UV, corrosion resistant __________ Color: White __________
Electrical Distribution Panel: UL Listed single-Phase 3 wire, 120/240V 100 A load center (NEMA 3R). Provide Rainproof and steel- (Ice-) resistant Outdoor enclosures for use outdoor to
protect the enclosed equipment against rain and meet the
requirements of Underwriter Laboratories, Inc., Publications No. UL 508, applying to “Rainproof Enclosures.” __________ Sump Accessories: 172 SqFt. High Density Polyethylene (HDPE) 20mil thick sump pump liner. __________
COMPLY YES/NO
Doors: Two (2) Heavy gauge 54” steel door located on front of
building. Hinges and hasp are attached to door by welding. The locking hasp is hooded with ¼” plate steel for extra security. T-handle rubber draw latch installed near hasp on entry door. __________
Ventilation: One (1) Steel frame and guard, aluminum 12”
blade, aluminum louver and totally enclosed motor. __________
Shelving: Three (3), 6’ heavy duty adjustable, steel
containment shelving with continuously welded 2” lip around entire shelf. __________
Interior Lighting: Three (3) Incandescent light fixture with clear thermal shock resistant glass globe, non-locations where the lamp, socket and wiring require protection from rain, corrosive fumes, non- combustible dusts and non-explosive vapors and gases. Must
comply with UL Standard 1598. __________
Exterior Lighting: One (1) Weather Proof Incandescent light
fixture with clear thermal shock resistant glass globe, non- locations where the lamp, socket and wiring require protection
from rain, corrosive fumes, non-combustible dusts and non- explosive vapors and gases. Must comply with UL Standard 1598. __________
OPTIONAL COMPONENTS: COST
Partition Walls: One (1) Interior Partition Wall for safe and secure segregation of materials. Manufactured 12 Gauge hot rolled Steel with ventilation. $__________
Access Ramp: 44” W x 88” L, fabricated from 12 gauge steel.
Color: Yellow, rated for 275 lbs per sq. in. $__________ D.O.T. PLACARD $__________