Implemented Amendment to change NAICS from 922160 to 33998 and to change PSC code from F003 to 4240Pyrotech Deluge Package Ultra high speed deluge system? RAM Qty 1 LAM Qty 3 RAM BP Qty 1 LAM BP Qty 3 Brass Solenoid Qty 12 CPF-74B Qty 12 Nozzles Qty 12 Or-check Qty 12 19 inch Rack Qty 1 Control Enclosure Qty 1 LaMarche Charger Qty 1 Battery Enclosure Qty 1 D171-AM Detector Qty 12 D171 Detector Mount Qty 12 Includes Pyrotech UHSD system components with the addition of a pre-wired control panel and power system engineered by Pyrotech plus an on-site visit by a Pyrotech technician. Visit includes commissioning (start-up, testing and training) and up to 3 days on site. Customized Ultra-High Speed Deluge Control Panel design and fabrication Ultra-High Speed Deluge Control Panel: Three part enclosure with viewing door? System Ready indication (green light) System Fault indication (amber light) System lamp test AC Loss indication (amber light) Supervised electrical manual discharge capability Adjustable auto reset (Automatic reset was initially developed to meet EPA requirements regarding contaminated water. The integral feature allows water to flow for a predetermined time from 0 to 90 seconds and automatically shut off. If, at any time in the predetermined time cycle, an alarm occurs, the RAM and any corresponding LAMs will actuate solenoids to provide deluge coverage. This feature can be field adjusted or bypassed) Supervision of the solenoid wiring for short, open and ground (amber LED for each fault) Supervision of the detector wiring for short, open and ground General form C alarm and fault contacts (i.e. external devices, machine shutdown, etc.) Relays with integral suppression and status LEDs for easier troubleshooting Individually fused zones? Custom Graphic Annunciator indicating zone alarm (on multiple zone panels). Required RAMs (Response Acceleration Modules) The RAM supervises solenoid and electrical manual pull circuitry (if electrical manual pulls are used) for short, open and ground faults. The RAM provides the required high speed, high voltage pulse to achieve the required system reaction speed. The RAM has a key switch to individually inhibit each zone if desired. The RAM has the required internal circuitry to provide automatic reset. The RAM has an integral test jack for system reaction time tests. Required LAMs (Low cost Acceleration Module) The LAM is a slave module to the RAM. The LAM supervises solenoid circuitry for short, open and ground faults. It controls up to four solenoids. The LAM provides the required high speed, high voltage pulse to achieve the required system reaction speed. (This module not required for this application.) Solenoids CPF-74B3 High Speed Deluge Valves Nozzles (38MA) Unitized UV/IR detectors and mounting brackets Battery charger Battery backup (sealed, lead-acid with gelled electrolyte, 8 hours backup / 16 hour recharge) Battery enclosure CAD generated drawings (electronic file) Mechanical manual discharge capability (control panel power is not required to activate this feature) Electrical control panel design Mechanical design assistance 1 set of system manuals (electronic file) Instrumentation and personnel necessary for startup, test and training (includes expenses and up to 3 days on site for each system) Delivery to your facility Pyrotech components are Made In USA 2 year warranty on all Pyrotech equipment 5 year warranty on Detector equipment