Specifications include, but are not limited to: Lighting Fixtures 2-1 Interior Surface Mounted 35 EA 2-2 Misc. Sconce 20 EA 2-3 Type X Exit 5 EA 2-4 Type W Exterior Wall Pack 7 EA Lighting Circuitry 3-1 3/4-inch Emt, 4 #12 1,241 LF 3-2 MC Cable 245 LF 3-3 Wiring Devices, Branch Circuitry 1,600 SF Power Equipment 4-1 100 Amp Panel Board 2 EA 4-2 New Meter Pans 2 EA 4-3 Demolish existing 75 kVA Electrical Service 1 LS 4-4 Upgrade Electrical Service to 100 kVA (TO BE VERIFIED) 1 LS 4-5 New automatic hand dryers (based on Xierator XL-BW-ECO) 2 EA 4-6 New Car Charging Stations 2 EA Provisions 2-1 5/8” CDX Exterior Sheathing 1,600 SF 2-2 2”x12” P.T. Joists 300 LF 2-3 1/2” x 8” S.S. Carriage Bolts 200 EA Division 31& 32 – Site Work 3-1 Concrete Curb – required for traffic containment at entrances 400 LF 3-2 Saw Cut Pavement 600 LF 3-3 Silk Fence North 800 LF 3-4 Pavement Sealing 22,000 SY 3-5 Asphalt Removal Allowance 2,000 SY 3-6 Asphalt Patch/Replacement 1,500 SY 3-7 Striping 20,000 LF 3-8 Signage Allowance 1 LS 3-9 Rain Gardens 7,000 SF 3-10 Fencing/Barrier Replacement Allowance 1 LS 3-11 Replacement Gates Allowance 1 LS 3-12 Concrete Retaining Wall 120 CY