Air Compressor must meet the following requirements:- Must have 230/460 Volt 3 phase- Direct coupled, will not accept belt driven compressor- Drive and fan motor must be totally enclosed, fan cooled- Extended service intervals should be 4000-hour fluid filter and 8000 hour separator- Must have a NEMA 4 electrical rating- Must have a low sound enclosure- Must have factory-filled 8000 hour QuinSyn-Plus Fluid- Wye Delta reduced voltage starter- AirLogic Advanced Intelligent Controller with Color Display- Must have a minimum of 20 horsepower- Must have a minimum of 97.2 ACFM flow - Must have a minimum of 125 PSIG full load pressure- Discharge size no less than 1? NPT- Maximum ambient temperature 115F- Minimum ambient temperature 32F- Must have a 3.43 gallon fluid capacity- Sound from compressor cannot exceed 67dBA- Dimensions must be as close to these dimensions as possible, 56.4L x 33.1W x 50.3 HWarranty Requirements:- 5-year airend warranty- 5-year drive motor- 5-year heat exchanger- 5-year separator tank