This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued. This acquisition is for a hazmat storage building/container for the 106th Rescue Wing of the New York Air National Guard, F.S. Gabreski ANG, Westhampton Beach, NY 11978. This is a 100% Small Business set-aside. The applicable NAICS code for this acquisition is 493190 and the size standard is 30 million dollars. Solicitation number F9E1PJ1139AW01 is being issued as a request for quote and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2021-05 Effective March 10, 2021. Firms must be registered in the System for Award Management (SAM) before an award can be made. To register with SAM, log on to https://www.sam.gov.
This Request for Quote will result in a firm fixed price contract. This announcement is the solicitation which will result in a firm fixed-price contract. Contract will be awarded to the contractor whom provides a quote that conforms to the terms and conditions of this combined synopsis / solicitation and meets all the requirements that is outlined and is determined responsible IAW FAR Subpart 9.104-1.
FOB: Destination
Include the following information on your quote: cage code, tax id number, company name, phone number, POC, signature of authorized representative and email. Offerors' quotes shall be valid for a minimum of 30 days to be acknowledged in the offerors' quote.
Offerors must have electronic funds transfer (EFT) capability. Contractors must be actively registered with iRAPT, formally the Wide Area Work Flow (WAWF) at http://wawf.eb.mil.
4HRBFR 15X7X9 21DRUM -S2 - 2 BAY STORAGE OR LIKE ITEM -1 EACH
Wind Load: 120 MPH Exp. C
Floor Load: 250 psf
Snow Load: 40 psf
Seismic: Category C
Sump Capacity: 311 Gallons
Drum Capacity: 21
-welding procedures are in accordance with the American Welding Society and meet standards set forth by the
ASTM, and all welds are sufficient in size and shape to accommodate wall designs and loads.
Four hour bi-directional fire rated, weatherproof construction that meets or
exceeds UL 263 and ASTM E-119.
Framework connected by welding. Construction consists of multiple
layers of UL Listed gypsum wallboard encased between Galvanneal steel sheets on interior and exterior faces for maximum
durability. Gypsum wall board layers are offset with overlapping joints. Mineral wool installed in the wall cavity with a R-
12 minimum rating.
ROOF SYSTEM: One (1) hour Per IBC Section 722, fire rated Class A flame spread rating. Wind uplift exceeds UL I-
60 and is constructed of 1 hour fire rated, weatherproof construction. Exterior roof sheets are continuously welded to roof
supports at each seam.
HRS steel roof with multiple layers of UL Listed fire resistant gypsum wall board lined
on the interior with galvanealed steel sheets on interior. Assembly meets or exceeds UL 263 and ASTM-E119. Roof is
sloped to facilitate runoff and door(s) are equipped with rain shields on exterior.
7/
COLOR,STD,BLEACHED BONE 1
COLOR - BLEACHED BONE
DOOR 36 X 80 3HR RIGHT STD 2
SINGLE DOOR, 36" WIDE X 80" TALL, 3 HOUR FIRE RATED UL CLASSIFIED & LABELED, 3 HOUR FIRE-RATED 36"W
X 80"H SINGLE DOOR. EQUIPPED WITH A UL LISTED DOOR CLOSER AND A UL LISTED EXTERIOR KEYED LOCK.
DOOR SERVES AS A ENTRANCE AND EXIT DOOR.
SL2 PART WALL 5-7 4HR STD 1
INTERIOR SEPERATION WALL FOR SL2 MODELS (5' - 7' NOMINAL WIDTH). 4HR-FIRERATED WALL
CONSTRUCTION, SEPERATION WALL EXTENDS FROM SUMP BASE TO CEILING.
LC 240V-1P 8 SPACE 100A 3R
UL LISTED, SINGLE PHASE, 3 WIRE, 120/240V 100 AMP 8 SPACE LOAD CENTER (NEMA 3R). RAINPROOF
AND SLEET- (ICE) RESISTANT- OUTDOOR ENCLOSURES ARE INTENDED FOR USE OUTDOORS TO PROTECT
THE ENCLOSED EQUIPMENT AGAINST RAIN AND MEET THE REQUIREMENTS OF UNDERWRITERS'
LABORATORIES, INC., PUBLICATION NO. UL 508, APPLYING TO "RAINPROOF ENCLOSURES." OTHER
ELECTRICAL CONFIGURATIONS AVAILABLE, ADDITIONAL COSTS MAY APPLY.
LIGHT C1D2 LED 2FT
LED LOW PROFILE, CEILING OR WALL MOUNT, 2FT NOMINAL LENGTH STRIP LIGHT. UL 1598A, 844, 1598, &
8750; CUL LISTED. CLASS 1, DIV 2, GROUPS A, B, C, & D. CLASS 2, DIV 2, GROUPS F & G. NEMA 4X. DESIGNED
FOR USE IN HAZARDOUS LOCATIONS AND WHERE MOISTURE, DIRT, DUST, CORROSION AND VIBRATION MAY
BE PRESENT. ALUMINUM BODY W/ GRAY EPOXY FINISH; T-ONE PIECE, NEOPRENE GASKET AND DIFFUSED
POLYCARBONATE LENS. 120-277/1, 50 OR 60HZ. 3620 LUMENS, 27 WATTS
EXPLOSION PROOF EXHAUST FAN 2
EXPLOSION PROOF EXHAUST FAN CONSISTING OF ONE (1) UL LISTED, CLASS I, DIVISION 1, GROUP C AND D
TOTALLY ENCLOSED EXPLOSION PROOF 1/4 HP 1800 RPM MOTOR (115VAC, 4.5A, 60HZ, 1-PHASE) WITH NONSTATIC
TWELVE-INCH (12) DIAMETER CAST ALUMINUM FAN BLADE, 1,160 CFM @ 0.0" SP. EXTERNAL HOUSING
CONSTRUCTED OF 18 GA STEEL. EXHAUST INTAKE VENTS LOCATED WITHIN TWELVE INCHES (12) OF THE
FLOOR. ACTIVATED BY AN EXTERIOR UL LISTED FAN SWITCH. EXTERIOR EXHAUST FAN PORT OPENING
EQUIPPED WITH SHUTTER ASSEMBLY AND SCREEN.
DRY CHEM 21LB 1
UL, ULC LISTED AND FM APPROVED PRE-ENGINEERED DRY CHEMICAL FIRE SUPPRESSION SYSTEM FOR CLASS
A,B AND C FIRES. EQUIPPED WITH MEANS FOR REMOTE ANNUNCIATION. SYSTEM INCLUDES FUSIBLE LINK
DETECTION FOR AUTOMATIC ACTUATION, MANUAL PULL STATION, AND NOZZLE(S) FOR TOTAL FLOODING
APPLICATION. AGENT STORAGE LOCATED ON BUILDING EXTERIOR IN WEATHERPROOF ENCLOSURE. AUDIBLE
ALARM INCLUDED WITH SYSTEM. DRY CHEMICAL SYSTEMS SHIP WITH A FULL TANK OF SUPPRESSANT,
PRICE MUST INCLUDE ARMING BY A LICENSED TECHNICIAN ONCE THE BUILDING IS ON SITE. IT IS THE
RESPONSIBILITY OF THE CUSTOMER TO ARRANGE AND COORDINATE THIS ARMING AND ANY RESULTING
TESTS OR OTHER MAINTENANCE. SOME OF THE ELECTRICAL COMPONENTS WILL NOT OPERATE UNTIL THIS
ARMING PROCESS HAS BEEN COMPLETED.
SHELVING 3 TIER SYSTEM 60
LINEAR FEET OF THREE TIERS OF SUMP SHELVING: ADJUSTABLE 16" LEAKPROOF STEEL SHELVING FORMED
AND WELDED FROM HEAVY GAUGE STEEL WITH A 2" LIP AROUND THE ENTIRE SHELF. SHELVING LENGTHS
ARE APPROXIMATE AND MAY VARY DUE TO SPACE LIMITATIONS. TOTAL PRICE IS CALCULATED FROM
QUANTITY OF LINEAR FEET QUOTED. WEIGHT CAPACITY: 75 LBS. PER LINEAR FOOT.
MUST INCLUDE FREIGHT.