The Consultant shall provide the design, specifications, bid/award and construction management services for the demolition and replacement of the existing bathroom and shower areas at the Voorhees Residential Community Home. The Consultant shall provide a design and layout for a new bathroom and shower room to meet Prison Rape Elimination Act compliance. The Consultant shall evaluate the existing bathroom and shower room. The evaluation shall include and identify, but not be limited to: room dimensions, door and window openings, room finishes, all bath and toilet fixtures, waste, drain, vent and water supply piping, floor drains, heating and/or cooling outlets, emergency and area light fixtures and electrical devices. The Consultant shall locate and identify the building’s mechanical, plumbing and electrical sources required for the project renovations. Design documents shall include site work access routes during renovation demolition and construction including material delivery and equipment. The required number of toilets, shower stalls, and sinks in these spaces shall be evaluated by the Consultant. However, the design shall not be less than the current quantity. All floor, wall and ceiling penetrations shall include all required safing, sleeves, fire stops, flashing, etc. as required to make a complete and code compliant installation. All new pipe materials, floor drains, hangers, pipe fastening materials and all other components of the new work shall be adequately sized and suitable for facilities of this type. All new installations shall comply with ligature resistant regulations and all applicable building codes and regulations. Demolition: The Consultant shall provide the demolition design and debris removal criteria required for the project. This shall include but not be limited to the demolition and removal and disposal of all tile walls and floors, fixtures, exhaust fans and lighting fixtures, electrical receptacles, etc. Electric/Lighting: The Consultant shall design all electrical requirements for the project to include but not limited to: replacement of the existing light fixtures, addition of new fixtures to provide an appropriate level of lighting, all required emergency and egress lighting, replacement of existing switches and receptacles including any required ground fault devices, addition of new devices as deemed necessary or appropriate by the proposed electrical design, any required disconnects, any required grounding, and any and all components necessary for a complete and code compliant system. The new light fixtures are to be sealed LED light fixtures with ligature resistant covers and, as necessary, have polycarbonate lenses. The Consultant shall determine if the existing circuitry and electrical service is sufficient for the proposed design. If not, provide necessary design elements to upgrade the service and provide sufficient circuits.