Specifications include, but are not limited to: 3.1 Installation of {2) chain link containment areas Furnish and install approx. 26 lf(linear feet)of 10' high, standard, galvanized, 9ga chain link fence as an emergency exit containment area (x2). Includes (1) 4' wide, access gate with built-in, single lock box (lockset furnished and installed by others). Also includes the top being fully enclosed and all bands and fittings being tack welded to the posts. Containment area to have (4) rails (top, bottom and two middle rails - to match existing containment area at another building, on site). Enclosed top cannot be attached to the building. There will be (2) identical containment areas on the same building. 3.1.6 One at the west side, emergency exit door and one on the north side emergency exit door. Each containment area to be approx. 8' long x 14' wide x 10' high (approx. 26 lf + top x 2). Installation of (1) chain link containment area 3.2.1 Furnish and install approx. 35 lf of 10' high, standard, galvanized, 9ga chain link fence as an emergency exit containment area (x1). 3.2.2 Includes (1) 4' wide, access gate with built-in, single lock box (lockset furnished and installed by others). 3.2.3 Also includes the top being fully enclosed and all bands and fittings being tack welded to the posts. 3.2.4 Containment area to have (4) rails (top, bottom and two middle rails-to match existing containment area at another building, on site). Enclosed top cannot be attached to the building. 3.2.5 There is only (1) containment area of this size, located on the same building as the two other containment areas referred above. 3.2.6 This one is located at the laundry exit doors 224 & 225. This containment area is to be approx. 8' long x 23' wide x 10' high (approx. 35 lf + top). Preparation of Installation Chain Link Fence 3.3.1 Vendor must prepare area for the laying of the concrete pads. 3.3.2 Vendor must contract out 3 concrete pads