Specifications include, but are not limited to: repair of one vertical lineshaft well pump, chlorination and removal of an existing variable speed drive. ; 1. Remove Pump No. 1 motor, shaft and pump from the well. Bidder may temporarily place them on wood blocks on the ground at the well site and leave the motor in the well house. Protect motor from elements. 2. Replace the broken 416 stainless steel line shaft. 3. Repair and overhaul Pump No. 1, including: ▪ Transport to shop. ▪ Disassemble, blast and clean. ▪ Document critical dimensions and clearances in “as-found” condition, shaft runouts; provide photos and sketches of critical components with comments pointing to possible root causes. ▪ Replace bearings. bushings, packings and interstage couplings. ▪ Replace or straighten shaft with documented method of strengthening. ▪ Replace mechanical seals. ▪ Inspect collets’ or cones’ martensitic stainless steel liner, impeller vanes and clearances. ▪ Restore clearances between impeller(s) and case liner(s).