1. GROUT JOINTS AT PORCELAIN TILE FLOORS AND WALLS TO BE 1/8", GROUT SHALL BE SEALED AFTER SETTING TIME RECOMMENDED BY MANUFACTURER. 2. PROVIDE EXPANSION JOINTS AS RECOMMENDED BY MANUFACTURER WITH SEALANT TO MATCH GROUT COLOR. 3. FOR FINISHES NOT INDICATED ON DRAWINGS, CONTRACTOR SHALL CONSULT ARCHITECT FOF ASSIGNMENT/CONFIRMATION OF FINISHES. 4. THIS SCHEDULE DOES NOT INCLUDE EVERY ITEM WHICH MAY REQUIRE A COLOR ASSIGNMENT; THOSE ITEMS WILL HAVE COLOR SELECTIONS MADE THRU THE SUBMITTAL PROCESS (INCLUDING BUT NOT LIMITED TO); TOILET PARTITIONS, MARKER AND TACK BOARDS, ETC. 5. SEE BUILDING SECTIONS, WALL SECTIONS, AND INTERIOR ELEVATIONS FOR ADDITIONAL FINISH MATERIALS AND REQUIREMENTS. SEE A600 SHEETS FOR CEILING TYPES. 6. PROVIDE A TRANSITION STRIP AT ALL EDGES OF DISSIMILAR MATERIALS, IE: TILE TO CARPET, TILE TO SEALED CONCRETE. COLOR AND PROFILE BY ARCHITECT. SUBMIT OPTIONS FOR APPROVAL. 7. ALL VCT SHALL HAVE GRAIN RUNNING IN SAME DIRECTION, PARALLEL TO SHORTER DIMENSION OF THE ROOM. 8. WALL FINISHES AS INDICATED, ARE TO BE FULL HEIGHT (FLOOR TO CEILING) UNO. 9. ALL INTERIOR CAULKING SHALL MATCH ADJACENT SURFACES UNLESS OTHERWISE NOTED. ALL JOINTS BETWEEN DISSIMILAR MATERIALS SHALL BE CAULKED. CAULK/SEALANT ALL JOINTS AT COUNTERTOPS AND BACKSPLASHES. 10. CHANGE OF COLOR SHALL OCCUR AT INSIDE CORNERS. DO NOT CHANGE COLOR ON AN OUTSIDE CORNER UNLESS NOTED OTHERWISE. 11. THE FOLLOWING ITEMS: HOLLOW METAL DOOR FRAMES, AIR GRILLES, LOUVERS, ACCESS PANELS, SHALL BE PAINTED TO MATCH ADJACENT WALL. UNO.