Specifications include, but are not limited to: 1. Product 1.Commercial Fleet non computing – Mechanical register 2.Type 1.Pump-integrated suction pump and motor 3.Flowrate-capable of delivery in typical installations 1.High Flow (HF) = 22 gpm Diesel 4.Models 1.Single product single hose-one fuel product unit with a single hose 20’ 5.Hardware 1.Display 1.MechanicalFleet: Veeder-Root® mechanical registers (VR10) with power reset interlock. Displays on both Sides include gallons to 999.9. Includes 8-digit non-resettable mechanical totalizer to 9,999,999.9. 2.Reset (Mechanical register models only) 1.Power Reset (standard)-motor driven mechanical register reset 3.Pulser (Electronic type) 1.Dual phase 100:1 with error detection 4.Meter 1.Four-piston, positive displacement flow-through CFT meter bilsters resistance to fuel contamination with self-cleaning central chamber.