Specifications include, but are not limited to: 1. Old Wastewater Tank a. Exterior paint system shall be as follows: Prime coat shall be a single component Aromatic Urethane Zinc primer, green in color, with a dry film thickness (DFT) of 2.5 to 3.5 mils, Tnemec Series 94-H2O Hydro Zinc, or approved equal. b. Second coat shall be Tnemec Series 66 H.B. Epoxoline, or approved equal (beige) with 3.0 to 5.0 mils DFT. c. Third coat shall be Tnemec 1074U EnduraShield or approved equal, with UV Blocker with 2.0 to 4.0 mils DFT. Owner will select final color from standard color charts furnished by Contractor 2. New Wastewater Tank a. Exterior paint system shall be as follows: Spot Prime coating system shall be Tnemec Series 135 Chembuild, or approved equal, green in color, with a dry film thickness (DFT) of 3.0 to 5.0 mils. b. The first full coat to be applied shall be Tnemec Series 1028 Enduratone, or approved equal (beige) with 2.0 to 3.0 mils DFT. c. Third coat shall be Tnemec 1028 Enduratone, or approved equal, with UV Blocker with 2.0 to 3.0 mils DFT. Owner will select final color from standard color charts furnished by Contractor d. Total paint thickness shall be a minimum of 7.0 to a maximum of 11.0 mils DFT. e. There shall be noticeable contrast in color between the second and third coats