Specifications include, but are not limited to: 2. WINDOWS Spec No. A-9201: STABILIZE WINDOW/REHAB Wet scrape all interior and exterior window components including sashes, jambs, stops and exterior sill. Reglaze as required. HEPA vacuum all visible dust. Spot prime interior and exterior with alkyd (oil) primer/sealer. ; 3. DOORS Spec No. A-9301: DOOR - STABILIZE AND PAINT Stabilize paint by wet scraping and HEPA vacuuming. Wet feather sand edges. De-gloss with a lead-specific detergent. Rinse, spot prime and top coat with owner’s choice of premium acrylic latex or alkyd enamel. ; 4. TRIM Spec No. A-9400: TRIM STABILIZE AND PAINT - INTERIOR ________/ LF Mist defective paint area with water. Lightly scrape all loose paint. Feather edges with a sponge sanding block saturated with de-glossing agent. Rinse and HEPA vacuum all visible chips. Allow surface to dry, seal and topcoat with premium acrylic latex or alkyd enamel. ; 6. FLOORS AND STAIRS Spec No. A-9610: VINYL TILE REPAIR Remove all damaged floor tiles, clean adhesive from deck. Install replacement tiles using manufacturer’s adhesive and specifications to create a cleanable surface. Match existing tile color and style as closely as possible.