Specifications include, but are not limited to:This contract includes system components, wiring, and labor, including incidentals necessary for the layout/design, installation, repair, maintenance, testing and inspection of Card Access Control Systems operating with Gallagher software. 1.02 DEFINITIONS A. Authority Having Jurisdiction (AHJ) - An organization, office, or individual responsible for enforcing the requirements of a code or standard, or for approving equipment, materials, and installation, or a procedure. The AHJ may be a Code official where governed by Code. B. Contracting Agency – State of MN Department of Natural Resources (DNR) or State of MN Pollution Control Agency (PCA) C. Owner of the Building – Any private or public entity that owns the facility where work is to be performed. In the case of leased space the owner of the building will be listed on the purchase order 1.03 SYSTEMS DESCRIPTION Card Access Control Systems a. System Software/Access Control Units (ACU) b. Reader – Types include proximity, wiegand, RFID, bar code, biometrics, and smart cards c. Position Sensor d. Request-to-exit device (RTE) e. Locking Systems 1) Electrically operated door hardware 24 VDC, unless indicated otherwise 2) Electrically operated lockset 3) Electrically operated mortise type lockset with integral RTE switch and door position switch 4) Electrically operated cylindrical type lockset 5) Electric strike 6) Electrically operated exit device with integral RTE switch 7) Magnetic lock – limited use (discouraged on egress doors)