Specifications include, but are not limited to: Installation of 69 card readers on 47 doors (22 doors are Read In / Read Out) 25 doors are single reader doors. Card Reader system to integrate with existing Jail Control System installed by Accurate Controls, points of connect will be provided for jail control integration. Access control panels must be installed into high density wall mounted enclosures in the lower level library next to the PLC cabinets. Provide QTY 50 - Net2 proximity ISO cards – without mag stripe. Part Number 692-500- US. System must incorporate a lockdown button installed in three control rooms. Lockdown button must disable all access control functions and prevent all cards from opening doors. Lockdown button shall be similar in appearance and function to the SS2421LD-EN from Safety Technology International (STI) System must utilize Paxton hardware and readers. Substitutions will not be accepted. Cable to card readers shall be plenum rated. Card Readers shall be Paxton P50 Mullion reader part number: 345-220-US. Software must be installed on existing county provided hardware. Provide door locking hardware and installation for 10 previously uncontrolled doors.