Specifications include, but are not limited to: Hardware The existing system is a 3xLogic Infinias system with single door cabinets and power supplies installed above each door. Each cabinet is connected via POE network cabling to the nearest Telecom Room. The District currently needs to add readers to an additional 4 doors (Doors 10, 14, elementary main office, & elementary main corridor). The existing readers are 125KHz, and wired for Weigand protocol. The new readers shall be dual frequency (125KHz & 13.56MHz) and capable of being wired for Weigand and OSDP protocols. The District needs all exterior doors to have door position sensors installed. A Building Map and Door Legend are provided at the end of this document. ● Green Indicates existing hardware (electrified hardware or/and card readers) ● Red Indicates locations with no existing access control hardware Software The District is looking to have ease of access to control badges, setup alerts, and automated reporting. The system must be an Genetec Security Center hosted on premise setup with the following presets: ● Ready to integrate video management to replace Milestone Security System ● Alerts to be sent to a team of people if doors are propped open for longer than a set period of time (Length TBD Later) ● Automated Reports to show both allowed/denied access if between the hours of midnight and 5am.