1.8 SCOPE OF WORK (GENERAL) A. New Servers, Panels and/or Appliances - See also section 28 00 00 as required. B. New card readers, request to exit devices, connection to electrified door hardware at new and existing locations. C. Door Contacts and PIR REX at all monitor-only doors as indicated on drawings. D. New lockdown and panic buttons E. New plenum-rated cabling for the connection of all devices including, but not limited to, card readers, REX, door contacts, electrified hardware and integration with handicap door operators. F. Installation and programming of access control software and associated hardware (including client interface software and badging computers, servers, etc.). G. Connect electric strikes and monitor status of door controls and door contacts H. Integration of existing handicap access buttons I. All cabling, wiring and connections required. J. All specialty conduit requirements. K. System Programming L. Training