All correspondence must be made through the Vendor Portal. Specifications include, but are not limited to: 1. Door Access Control: Fitchburg High School: • Install (65) Category 6 Cable runs to the camera locations split between 3 floors • All cabling will follow existing cable above the drop ceiling • All cabling will be brought back to the nearest network closet o Install Category 6 cabling for the (7) outside camera locations o Install (5) cable for the Door Access Control unit above ceiling (door to be pre-wired and electric door strike) • Jacks will be installed either above the drop ceilings or mounted to a wall on a single port surface mount • In the MDF or IDF, mount (1) 24 port open frame patch panel in an existing open space in the rack • Test for Category 6 Specifications Crocker Elementary School: • Install (5) Category 6 Cable runs to the exterior camera locations o All cabling will follow existing cable above the drop ceiling o All cabling will be brought back to the nearest network closet • In areas with no drop ceilings or in an area where ceilings cannot be touched, use EMT pipe below the ceiling to the camera location • Install (1) cables for Door Access Control units above the ceiling (door to be pre-wired and electric door strike) • Jack will be installed either above the drop ceilings or mounted to a wall on a single port surface mount • In the MDF or IDF, will mount a 24-port open frame patch panel in an existing open space in the rack • Test for Category 6 Specifications Goodrich Academy: • Install (4) Category 6 Cable runs to the exterior camera locations o All cabling will follow existing cable above the drop ceiling o All cabling will be brought back to the nearest network closet • Install (1) cable for Door Access Control unit above the ceiling • In areas with no drop ceilings or in areas where ceilings cannot to be touched, use EMT pipe below the ceiling to the camera location • All cabling will be pulled back to the MDF network closet • Jack will either be above the drop ceilings or mounted to a wall in a single port surface mount • In the MDF, mount a 24-port open frame patch panel in an existing open space in the rack • Test for Category 6 Specifications South Street Elementary School and Administration: • Install (8) Category 6 Cable runs to the exterior camera locations o All cabling will follow existing cable above the drop ceiling o All cabling will be brought back to the nearest network closet • All cabling to follow existing cable above the drop ceiling where available • In areas with no drop ceiling or in areas where ceilings cannot be touched, use EMT pipe below the ceiling to the camera location • All cabling will be pulled back to the nearest network closet • Install (2) cables for Door Access Control units above ceiling • Jacks will be installed either above the drop ceilings or mounted to a wall in a single port surface mount • In the MDF or IDF, mount a 24-port open frame patch panel • Test for Category 6 Specifications Longsjo Middle School: • Install (6) Category 6 Cable runs to the exterior camera locations o All cabling will follow existing cable above the drop ceiling o All cabling will be brought back to the nearest network closet • Install (54) Category 6 Cable runs to the interior camera locations o All cabling will follow existing cable above the drop ceiling o All cabling will be brought back to the nearest network closet • All cabling will follow existing cable above the drop ceiling where available • In areas with no drop ceilings or in areas where ceilings cannot to be touched, use EMT pipe below the ceiling to the camera location • All cabling will be brought back to the nearest network closet • Install (3) cable for Door Access Control units above ceiling • Jacks will either be installed above the drop ceilings or mounted to a wall in a single port surface mount • In the MDF or IDF, mount a 24-port open frame patch panel in an existing open space in the rack • Test for Category 6 Specifications