Specifications include, but are not limited to: Building Details: • Freestanding metal frame structure 20’-0” wide x 20’-0” long x 8’-0” eave height on a concrete slab. • Built in accordance with all current ICC codes as adopted by the State of Maryland and Anne Arundel County, with amendments • Square Footage: Approximately 400 sf • Wind Speed: Per current code • Ground Snow Load: Per current code • Project Location: Various; see attached maps. • Bidder is responsible for all local (city, township or county) code compliance. Bidder is responsible for obtaining building permit. Foundation: • The foundation shall rest on sound soil that is free of organic and deleterious materials and capable of supporting 2000 psf vertical bearing pressure and 100 psf/ft lateral bearing pressure. • Foundation design shown based on the minimum soil strengths from the specified building code. Structural Plans: • Bidder to provide State sealed structural plans as required by Authority Having Jurisdiction (AHJ) • Bidder to provide Architectural and any site plans/approvals as required by AHJ • Permit, inspection or other municipal fees or services to be paid by Owner. Excavation & Footings: • Wet pour footings to code by Bidder. • Included: Back-fill, pad prep and any other excavation • Excluded: Soft and Unsuitable Soil, Hazardous Material Removal, Rock Excavation or Blasting; Site work, Landscaping, Fine Grading, Seeding/Storm water management, E&S Controls; surveying / Geotechnical Reports / Land Development Planning • Excluded: Concrete testing