Specifications include, but are not limited to: A. This work includes providing all material, labor, equipment, tools, and incidentals necessary to completely remove and dispose of approximately 1,360 square feet of existing concrete slab/tile flooring as designated on the attached Project Drawing. This work also includes providing and placing additional stone as needed to prepare for placement of the new slab. B. The new slab shall be 4-inch thick 3,500 psi concrete with 6x6-W2.9 x W2.9 welded wire reinforcement and 6-mil poly vapor retarder. Placement of new slab shall be installed by the Contractor after the owner has completed the installation of underground plumbing. Surface of new concrete slab shall be level with adjacent building slab. The work shall include coordination with other trades as needed to complete the renovation of the building. The Contractor shall submit all applicable material specifications and samples to the County for review and approval prior to the start of the work. Work will be performed with the floor unoccupied except for other trades that may be working in the same area.