Specifications include, but are not limited to: providing all engineering, supervision, materials, labor, and safety requirements for furnishing and installing new CCTV IP cameras, network switch/s, NVR(s), Workstation(s) fiber optic cabling/subduct, fiber optic patch panel and mini rack/s for BCF in Jessup, Maryland. All cabling will be CAT-6E or better encased in 1” (min) EMT, if above ceiling or above 12’ AFF. If below 12’ AFF, then rigid conduit required. There are fifty (50) cameras at BCF: (50) 5.0 MP IP-Vicon V945D-W310MIR All cameras will connect, by way of CAT-6E, to Master Control located on the First Floor. Master Control will also house: (1) new rack (Trippe Lite SR42UBDPWD) (1) new switch (Netgear GS748TP) (1) new Network Recording device (Vicon VPK-34TBV8-R5) (1) new Vicon Nucleus (VNUC-V8-1) (1) UPS unit capable of running the nucleus and NVR for five minutes (APC-SMX2000LV) There will be one (1) new workstation installed at Master Control.