Specifications include, but are not limited to: Vender will provide and install all of the equipment listed to Baltimore Police Department, 7th Floor Family Crime Unit. Vendor will provide (3) Access control card readers for the doors in the Family Crime Unit located on the 7th floor of BCP-HQ as follows; Main Entrance- Shall receive (1) card reader, (1) electric strike, (1) RTE/PIR and (1) recessed alarm contact. Administration Entrance- Shall receive (1) card reader, (1) electric strike, (1) RTE/PIR and (1) recessed alarm contact. Interior Door - Shall receive (1) card reader, (1) electric strike, (1) RTE/PIR and (1) recessed alarm contact. To control, power and monitor the doors the vendor will provide and install (1) Amag 4 door controller, (1) 6 amp device power suppiy with built in PDU and Battery back-up and (1) Network Interface. Vendor will provide all of the necessary low voltage cable to complete the installation. BCP will provide a Network Connection for the new Network Interface board, an IP address and access 120VAC. NO Substitutes Allowed.