Specifications include, but are not limited to: Quantity of 4 - ISCO 6712 Automated Samplers must include controller, top cover, center section, base, distributor arm, and two pump tubes. A. Each sampler must include a 12-botle configuration for the 6700 Series Full-size Portable Sampler. This must include twelve polypropylene 1-liter round bottles with caps, base locating insert, bottle retaining ring, and two discharge tubes. B. Samplers must include a six ft. connect cable for an external 12 VDC source and 4 deep cycle 12V batteries C. Each sampler must include a 100 foot, 3/8” suctuon line with a stainless steel strainer D. Each sampler must include an interface cable (TIENet® 306) for a watertight connection between the autosampler and the flowmeter. E. Each sampler must include Flowlink Cipher for up to 9 active sites. Quantity of 3 - Signature® Bubbler flowmeter systems with base station with internal bubbler. A. Each flowmeter must include a cable to connect to external 12 VDC to power Signature® meter. 10 m (33 ft) length B. Each flowmeter must include a 1/8 inch x 100 ft. vinyl bubble line. C. Each flowmeter must include a stainless steel bubble tube - 4 ft. length. For use with 1/8 inch ID vinyl bubble line. D. Each flowmeter must include an LTE North America and International cellular modem with magnetic mount antenna for Signature® meter. E. Each flowmeter must include a one year ICell subscription for cellular service with 10MB/month data and 25 SMS/month Quantity of 1 - Signature® Area Velocity flowmeter system must include TIENet™ 350 Ex Area Velocity sensor with a 10 ft (3.0 m) measurement range with 75 ft (23 m) cable. A. Flowmeter must include a LTE North America and International cellular modem with magnetic mount antenna for Signature® meter. B. Flowmeter must include a one year ICell subscription for cellular service with 10MB/month data and 25 SMS/month Quantity of 2 - Sensor mounting plate and carrier for area/velocity sensor Quantity of 1 - ISCO 674 Rain Gauge. Tips every 0.01 inch of rainfall. Tipping bucket rain gauge with 50 ft. cable and connector to 6700 Series/Avalanche Sampler. Quantity of 3 - Locking Aluminum Enclosure Large - NEMA 3R, 22.625-in x 26.5-in x 17-in Quantity of 1- VPC Fiberglass FRP “Stormbox” Shelter. Insulated (R7). Clam Shell Access 39 x 28 x 36 Includes Standard Stainless Steel Hardware, and Lifting Arm Quantity of 4 - 120 wat solar panel kit. Must include charge controller, output cable, mounting bracket, and Reg-batery cable Quantity of 1 - Initial start-up and installation for each sampler. Must provide initial equipment start-up, instrument programming, preparation and adjustments, calibration, operator training and certificate of proper operation. Warranty: Must provide at least a 12-month warranty covering parts and labor for all items.